258 Emphasis Console v2.0.0 User Manual
Wiring Remote Macros
Express facepanels
There are three typical ways to wire the Remote Macros:
#1: Connect all -Macro pins (pins 2, 4, 6, and 8) to ground (pins 12 and 13) and switch the
leads connecting the +Macro pins (pins 1, 3, 5, and 7) to +12 Vdc (pins 14 and 15) as
shown in the following diagram.
#2: Connect all +Macro pins (pins 1, 3, 5 and 7) to +12 Vdc (pins 14 and 15) and switch the
leads connecting the -Macro pins (pins 2, 4, 6 and 8) to ground (pins 12 and 13).
#3: Provide your own power supply that generates a 12 Vdc potential between the +Macro
and -Macro pins and switch either of these leads.
6
7
8
9
10
11
12
14
15
13
+Macro 1901
+Macro 1902
+Macro 1903
+Macro 1904
-Macro 1901
-Macro 1902
-Macro 1903
-Macro 1904
Remote Trigger NC
Remote Trigger NO
Remote Trigger C
Ground
Ground
+12 Vdc fused
+12 Vdc fused
1
2
3
4
5